Featured Work
- Details
6" hot tap for County of San Bernardino in Oak Hill, California
Job Date: November 27, 2017
JOB LOCATION: Seattle, WA.
PROJECT: 8" Pipe Freeze Plugs
Job Specifics:
Item I – 6” Hottap on Transite – A/C Waterline under 150 psi.
1 – 6” Hottap on Transite – A/C Waterline – below ground under 150 psi (Hottap ONLY on your pre-installed fittings and Valve)
Office hours 7:30 – 5:00 Central time
Nationwide: 1-800-221-3332
Emergency Services Available .
- Details
28" Linestop with 20" hot tap for bypass in San Francisco, California
Job Date: January 31, 2017
JOB LOCATION: San Francisco, CA.
PROJECT: 28" Linestops and 20" hottaps
Job Specifics:
Item I: Linestop® on 28” OD HDPE Gravity Raw Sewer Main Pipeline 60 psi (approx) With 20” By-pass Outlet.
1 – Mobilization – Prep / Travel to site
2 – 28” Linestop Fittings for 28” OD HDPE Sewage Pipeline (100 psi or less) (JCM Epoxy Coated Fitting w/ Stainless Steel Bolts)
2 - Installation of Saddle with Air Test
2 - Hot Tap Pipeline for Linestop entry
2 – Insertion of 28” Linestop for up to 12 Hours while others perform pipeline work.
2 - By-pass Outlets (20”) off Linestop Machines, with
2 - 20” Knife Gate Loaner Valves
2 – Removal of Linestops, install Completion Plugs and Blind Flanges
2 - 2” Saddle w/ Corp. Stop and Tap for Blow Down and equalizing pressure to remove Linestop (if Required)
Office hours 7:30 – 5:00 Central time
Nationwide: 1-800-221-3332
Emergency Services Available .
- Details
Two 1/2” pipe freeze plugs on copper pipeline to isolate the supply and return loop system of a hospital
Job Date: November 27, 2017
JOB LOCATION: Chula Vista, California
PROJECT: 8" Pipe Freeze Plugs
Job Specifics:
Item I – .5” - FreezePlug on Domestic Copper Water Line – under 120 degrees (F)
2 – .5” FreezePlugs on .5” Copper waterline, under 120 degree (F) Under 150 psi. FreezePlugs held for up to 2 hours each freeze while you perform modifications to the pipeline
Office hours 7:30 – 5:00 Central time
Nationwide: 1-800-221-3332
Emergency Services Available .
- Details
12" Linestops on Transite Pipeline in Laguna Niguel, California
Job Date: December 1, 2017
JOB LOCATION: Laguna Niguel, CA.
PROJECT: 12” Linestop
Job Specifics:
Item I: 12”Linestop® on A/C Water Main Under 120 psi – No By-pass
2 – Mobilization - Prep / Travel to site – One to Set L/S & One to Remove L/S
1 – 12” x 12” Linestop® Fitting for A/C Pipe (O.D. 14.32”)
(JCM 432 Style - Stainless Steel w/SS Bolts and Carbon Steel Linestop Flange)
1 – Installation of temporary valve with air test.
1 – Hot Tap to allow for Linestop® entry
1 – Insertion of 12” Linestop® – held for up to 3 days while Contractor performs Pipeline modifications
1 – Removal of Linestop® installation of completion plugs and Blind Flanges Installation of Blow-off assemblies as required for removal of Linestop®
Office hours 7:30 – 5:00 Central time
Nationwide: 1-800-221-3332
Emergency Services Available .
- Details
6" Stainless Steel Pipe Freeze Plugs at the Del Mar Fairgrounds in Del Mar, CA.
Job Date: November 27, 2017
JOB LOCATION: Del Mar Fairgrounds, California
PROJECT: 6" Pipe Freeze Plugs on Stainless Steel Pipe
Job Specifics:
Item #I 6” FreezePlug on Sch. 10 Stainless Steel Hot Water Pipeline – Under 110 (F)
1 – Mobilization – Prep / Travel to Site
2 – 6” FreezePlug on Sch. 10 Stainless Steel Pipelines under 100 PSI / 110 degrees or less
2 - Hold FreezePlugs on Hot Water Pipelines for up to 4 hours each.
IFT was called in to Freeze the 6” copper pipe so the defective valve could be replaced without a shutdown of the system. Once the Freezeplug is achieved the defective valve is replaced with a new valve.
Countless valves in America have been successfully replaced over 37+ years
Office hours 7:30 – 5:00 Central time
Nationwide: 1-800-221-3332
Emergency Services Available .