California

IFT Featured California Job: 5” Pipe Freeze Plug and 6" Linestop for St. Joseph Hospital - 5.0 out of 5 based on 5 reviews

User Rating: 5 / 5

Star ActiveStar ActiveStar ActiveStar ActiveStar Active

5” Pipe Freeze Plug and 6" Linestop for St. Joseph Hospital

5inch Freeze Plug and 6inch Linestop for St. Joseph Hospital

Job Status: Successful and Completed
Job Date: October 19, 2015
JOB LOCATION: Santa Ana, CA. PROJECT: FreezePlugs / Linestop
Job Specifics:
Item 1.
1 - 5” Indoor Pipe  Freeze Plug on 5” Carbon Steel Water Pipe
1 - Travel to job site
1 – 5” FreezePlug on Carbon Steel Water Pipe under 150 PSI / 100 degrees or less
1 - Hold FreezePlug for up to 4 hours each. Item 2. 6” Linestop on 6” Carbon Steel Domestic Water Pipe
1 – 6” Linestop fitting for Domestic Carbon Steel Water Pipe under 150 PSI / 100 degrees
1 - Weld on Tapping Saddle
1 - Pressure test fitting and Hot Tap pipe.
1 - 6” Linestop held for up to 4 hours while you perform pipeline modifications
1 - Removal of Linestop and installation of completion plug with cap. Blow-off assembly as required.

OR Call

Office hours 7:30 – 5:00 Central time

Nationwide: 1-800-221-3332

Emergency Services Available .

 

 

IFT Featured California Job: 30" Hottap for a 42" Linestop in Santa Maria, California - 5.0 out of 5 based on 7 reviews

User Rating: 5 / 5

Star ActiveStar ActiveStar ActiveStar ActiveStar Active

IFT Featured California Job: 30" Hottap for a 42" Linestop in Santa Maria

30” Hottap for a 42” Linestop in Santa Maria, California

Job Status: Successful and Completed
Job Date: June 22, 2017
Location: Santa Maria, California

Job Specifics:
ltem l: Linestop® 42” CMLC Water Main – under 150 psi (approx 80 psi)
2 – Mobilization – Prep / Travel - Install 42” Linestop® & Remove Linestop®
1 – 42” Linestop® fittings for CMLC Water Pipeline (100 PSI or less)
1 – Installation / Welding of saddle with air test.
1 – Hot Taps to allow for Linestop® entry
1 – Insertion of 42” Linestop® – Linestops Held for up to 7 Days
1 – 2” Saddle with Corp. stop and tap for blow down and equalizing pressure to
remove Linestop®, as required
1 – Removal of Linestops®, install Completion Plugs and Blind Flanges

Linestop® • Valve Inserting • Pipefreeze® • Large Tapping
Linestop® is a registered Trademark and Servicemark of International Flow Technologies, Inc. 

OR Call

Office hours 7:30 – 5:00 Central time

Nationwide: 1-800-221-3332

Emergency Services Available .

 

 

30" Hottap for a 42" Linestop Made the News in Santa Maria, California

SANTA MARIA, Calif. - The city of Santa Maria is asking people to conserve water over the next two days. The voluntary request is from June 21 through June 22, while the city completes a major water main project on McCoy Lane, just west of Skyway Drive. During these two days, the amount of available water will be reduced significantly because the city's main water production facility will be shut off to the public. In preparation, the city has been filling their water storage tanks. They have about 18 million gallons of water in those reserves now to be used by people living in Santa Maria over these two days. A week ago, crews started digging up about 10 feet of dirt to work on a 42-inch-diameter concrete-lined steel pipe. Wednesday and Thursday, they'll be adding a valve to the pipe to allow the city to do further work at the city's blending station at a later date. Jim Ellis is answering the call and doing his part in the name of water conservation. We made the adjustment, we turned off our landscaping water for tomorrow," Santa Maria resident Jim Ellis said. The city of Santa Maria is asking people to voluntarily conserve water for Wednesday and Thursday, while they complete a major water main project on McCoy Lane, just west of Skyway Drive. "We want to do our part to help out," Ellis said. Ellis and other Santa Marians can help out by not watering their lawns for these two days. "We all know how important water can be, just coming off of a drought," Ellis said. In preparation, the city filled their water storage reserve tanks with about 18 million gallons of water, to be used by people living in Santa Maria over these two days. "We're actually drilling into it to access into the pipe to plug it so they don't have to shut the whole system down," technician Tom Harrison said. Technician, Tom Harrison, says the city goes through about 17 million gallons of water a day - which is close to the 18 million gallons of water the city has in its reserve for these two days - but Harrison says the project is really only supposed to take half a day and that even if the city went through their reserve water, there's nothing to worry about because the city always has two backup plans. "They have a loop system that back feeds everything.. the other one is another backup system that's tied into that one also, just in case for really a backup," Harrison said. The project will allow the city to do further work at the city's blending station at a later date. The blending station is where chlorine and small amounts of ammonia are added to the water to disinfect it. "Lawn's not going dead, but I still feel like we're helping and I think everybody should still be mindful that we're not totally out of the woods yet just because we had a wet year this year," Ellis said. A major water main project on McCoy Lane, just west of Skyway Drive in Santa Maria. (Sean Larsen / KCOY photo) There are cones and signs up there but traffic is allowed to go through. People living in the city are asked to voluntarily conserve water and wait to water your lawns until this period is over. This is a great news story how our services helped Santa Maria's residents and the credits go to this excellent news station here, https://www.keyt.com/news/santa-maria-north-county/santa-maria-residents-asked-to-conserve-water-as-major-water-main-project-gets-underway/555304182

IFT Featured California Job: 6" Hottap on 6" Schedule 40 Carbon Steel Condenser Waterline under 100 psi - 5.0 out of 5 based on 3 reviews

User Rating: 5 / 5

Star ActiveStar ActiveStar ActiveStar ActiveStar Active

Chula Vista, Police Station Facility 6" Hottap on 6" Schedule 40 Carbon Steel Condenser Waterline under 100 psi

Chula Vista, Police Station Facility 6inch Hottap on 6inch Schedule 40 Carbon Steel Condenser Waterline under 100 psi

Job Status: Successful and Completed
Job Date: August 31, 2017
JOB LOCATION: Chula Vista, CA
PROJECT: Police Station Facility Hottap
Job Specifics:
ITEM I – 6” Hottap on 6” Sch. 40 Carbon Steel Condenser Waterline - under 100 psi.
2 – 6” Hottap on 8” Sch. 40 Carbon Steel Condenser Waterline – under 100 psi
2 – 6” x 6” Weld-on Full Wrap Tapping Sleeve - Flanged Outlet
2 - 6” Full Port Flanged Valves – ‘EXCLUDED’ CUSTOMER TO SUPPLY VALVES
2 - Welding of Materials w/ pressure tests  

ITEM II – 10” Hottap on 10” Sch. 40 Carbon Steel Condenser Waterline - under 100 psi.
1 – 10” Hottap on 8” Sch. 40 Carbon Steel Condenser Waterline – under 100 psi
1 – 10” x 10” Weld-on Full Wrap Tapping Sleeve - Flanged Outlet
1 - 10” Full Port Flanged Valves – ‘EXCLUDED’ CUSTOMER TO SUPPLY VALVES
1 - Welding of Materials w/ pressure tests 

OR call

Office hours 7:30 – 5:00 Central time

Nationwide: 1-800-221-3332

Emergency Services Available .

 

 

IFT Featured California Job: 4" Hot Tap on 10" Sch. 40 Steel Chilled Water Line under 150 psi - 5.0 out of 5 based on 4 reviews

User Rating: 5 / 5

Star ActiveStar ActiveStar ActiveStar ActiveStar Active

Warner Bros Studio 4” HotTap on 10” Sch. 40 Steel Chilled Water Line under 150 PSI

Warner Bros Studios 4inch Hot Tap on 10inch Sch. 40 Steel Chilled Water Line under 150 psi

Job Status: Successful and Completed
Job Date: October 02, 2017
JOB LOCATION: Burbank, Ca.
PROJECT: Warner Bros Studio Hottap
Job Specifics:
Item #I
– 4” Hottap on 10” Sch. 40 Steel Chilled Water Line under 150 psi 
– 4” Hottap on 10” Sch. 40 Steel chilled water line under 100 psi
– 4 - 10” x 4” Weld-on Threaded Hottap Fitting
– 4 - Welding / Installation of Fittings with pressure test (See Welding Notes)
– 4 - 4” Full Port Threaded Ball Valves - Apollo/Conbraco 70 series (Domestic) or equal

OR Call

Office hours 7:30 – 5:00 Central time

Nationwide: 1-800-221-3332

Emergency Services Available .

 

 

IFT Featured California Job: 8" Linestop on Sch. 40 Carbon Steel Steam Condensation line Under 100 psi - 5.0 out of 5 based on 2 reviews

User Rating: 5 / 5

Star ActiveStar ActiveStar ActiveStar ActiveStar Active

Mercy Hospital 8” Linestop on Sch. 40 Carbon Steel Steam Condensation line Under 100 psi 

Mercy Hospital 8” Linestop on Sch. 40 Carbon Steel Steam Condensation line Under 100 psi

Job Status: Successful and Completed
Job Date: June 06, 2017
JOB LOCATION: San Diego, Ca.
PROJECT: Mercy Hospital
Job Specifics:
Item I – 8” Linestop on Sch. 40 Carbon Steel Steam Condensation line Under 100 psi
1 – Mobilization Prep / Travel to site to perform Linestops
1 - Provide 8” Linestop fitting for Sch. 40 Carbon Steel Water Pipe - under 140 degrees
1 – Install / Weld-on Fittings, Pressure test Fittings and Hottap pipeline (See Welding Notes)
1 – 8” Linestop Installed and held for up to 6 hours ea. (While pipeline modifications are performed by others)
1 – Removal of Linestops and install completion plug with Blind Flange. Blow-off assemblies as required

Item II – 8” x 4” Hottap on Sch. 40 Carbon Steel Steam Condensation line Under 100 psi
1 – Mobilization Prep / Travel to site to perform Hottap (Same Mobilization as Linestop)
1 - Provide 8” x 4” Flanged fitting for Sch. 40 Carbon Steel Water Pipe
1 – Install / Weld-on Fittings, Pressure test Fittings (See Welding Notes)
1 - 4” Hottap on Carbon Steel Pipeline NOTE: Excludes Valve, ‘Others’ to Supply Flanged Valve per Specifications